Linear Smoke Alarm DF 72 EC User Manual

DESCRIPTION  
NOTE: After replacing batteries, press transmitter test button to reset  
The DF-72/EC is a high quality, photoelectric smoke detector with a  
built-in supervised digitally-coded radio transmitter. The DF-72/EC  
monitors and then transmits alarms, low battery, and test signals. The  
DF-72/EC sounds a local alarm as soon as smoke is detected. Twenty  
seconds after the local alarm sounds, the DF-72/EC’s transmitter  
will send an alarm signal to the console. The alarm signal will  
be repeated every 20 seconds as long as smoke is still present.  
DF-72/EC  
“low battery circuit”  
BY  
SMOKE  
DETECTOR  
For Use with DF-16/EC  
Security Console  
Coding switches are not required or used in the DF-72/EC. Each transmitter  
is pre-coded at the factory to a unique code. With the DX format, there are  
more than one million codes possible.  
Installation  
Instructions  
The smoke detector and transmitter are powered by two 9-volt  
batteries. These batteries are supplied with the transmitter and can  
power the unit for up to two years. If the battery voltage drops below  
a preset level, a low battery report is sent to the receiver every hour.  
(760) 438-7000 • FAX (760) 438-7043  
STEP 1 Remove mounting plate. Remove the unit’s mount- STEP 2 Identify components. Examine the DF-72/EC to STEP 3 Install batteries. Connect the two 9-volt batteries  
ing plate by turning the plate counterclockwise.  
identify the component locations.  
and place them into the battery compartments.  
TRANSMIT LED  
TWIST MOUNTING  
PLATE TO  
UNLOCK  
REMOVE  
MOUNTING  
PLATE  
TRANSMITTER  
BOARD  
TRANSMITTER  
TEST BUTTON  
CONNECT AND  
INSTALL TWO  
9-VOLT ALKALINE  
BATTERIES  
BATTERY  
COMPARTMENTS  
STEP 4 Pick smoke detector location. Referring to the STEP 5 Install mounting plate. Use the two screws and STEP 6 Program into receiver. Follow the DF-16/EC  
anchors provided to attach the mounting plate to the wall or  
ceiling. Alternately, the mounting plate can be attached to a  
plastic single-gang electrical outlet box. For the best radio  
range, observe the “best signal” label on the bottom of the  
unit.  
NFPA standard on the back of this sheet, select a good loca-  
tion to mount the DF-72/EC. Mounting the DF-72/EC on foil-  
backed wallpaper or on a metal single-gang electrical box is  
not recommended because the radio range will be reduced.  
console’s instructions to set it in a program or learn mode.  
Press the transmitter test button (not the smoke detector’s test  
button) to send a test signal. The transmit LED should light.  
Verify that the signal was received and that the transmitter was  
properly entered into the console’s memory.  
START IN  
OFF MODE  
SEND SIGNAL  
FROM SMOKE  
DETECTOR  
SCREW  
ENTER YOUR  
SECRET CODE  
PRESS  
LEARN UNUSED SENSOR  
NUMBER  
ENTER AN  
ANCHORS  
FOR WALLBOARD  
DINING  
KITCHEN  
BEDROOM  
BEDROOM  
LEARN BUTTON  
RED TEST  
LIGHT  
SMOKE  
DETECTOR  
PLASTIC  
SINGLE-GANG  
ELECTRICAL  
BOX  
LIVING  
ROOM  
OR  
BEDROOM  
PRESS AND RELEASE TRANSMITTER  
TEST BUTTON TO SEND A TEST SIGNAL  
HOLD OFF BUTTON FOR 3 SECONDS  
WHEN FINISHED TO EXIT LEARN MODE  
 

Lennox Hearth Indoor Fireplace ELDV3530 User Manual
LG Electronics Blu ray Player HB806TM User Manual
Lindy Network Card 70963 User Manual
Logitech Speaker 984 000193 User Manual
MABIS Duro Med Blood Pressure Monitor Semi Automatic Blood Pressure Monitor User Manual
Makita Chainsaw UC3020A User Manual
Melissa Toaster 243 002 User Manual
Metabo Drill 600581420 User Manual
Metra Electronics Automobile Accessories 95 9012 User Manual
Metra Electronics Network Card LC GMRC LAN 01 User Manual